Page 55 - Virtual Vascular Vol 6
P. 55

Left brachiocephalic vein

 Rightt brachiocephalic vein
 Elastic recoil with residual

 50% stenosis




 Superior vena cava

 40% stenosis



























 Post balloon angioplasty showed elastic recoil of the stenosis.  A 16mm x 60mm stent
 was deployed at the left brachiocephalic vein.



       Completion central venogram showed satisfactory result. The SVC
       40% stenosis was kept observed.


       Clinically the thrill along the AVF has much improved after the balloon

       angioplasty and stenting.  The patient continues to have dialysis via needling
       Of his left brachiocephalic AVF the next day. There was no increased in
       venous pressure during dialysis and haemostais of his needling sites was

       without difficulty.


       The left brachiocephalic vein and SVC stenosis was due to injury by the

       prolonged usage left central venous catheter for dialysis. During dialysis,
       the catheter tip is actually flipping and hit the vein wall constantly,
       inducing intimal injury and subsequently an inflammatory response

       leading to progressive stenosis.





 54                                                                                                            55