Cold Stimulation Test




 Laboratory tests included a raised C-reactive protein (CRP), positive anti-double

 stranded DNA antibodies, positive cardiolipin IgG levels, and positive anti-Ro and
 Anti-La antibodies.



 Anti-double stranded DNA (Anti-dsDNA) antibodies are a group of anti-nuclear
 antibodies (ANA) that are are highly diagnostic of systemic lupus erythematosus
 (SLE) and are implicated in the pathogenesis of lupus nephritis. Anti-cardiolipin

 antibodies are positive in patients with antiphospholipid syndrome, livedoid
 vasculitis, Behçet's syndrome, idiopathic spontaneous abortion, and systemic lupus
 erythematosus. Autoantibodies directed against Ro/SSA and La/SSB autoantigens

 are common in patients with Sjögren's syndrome and systemic lupus
 erythematosus, and other autoimmune diseases.



 ECHOcardiogram and Holter tape investigations were negative, ruling out proximal
 emboli source from the heart.



 We further perform a cold stimulation test, which is designed to trigger and
 simulate Raynauld’s symptoms: i.e. pallor on exposure to cold with
 vasoconstriction and rubor or rewarming due to vasodilatation. The waveform and

 pressure of each finger are measured by photophlethysmography (PPG), using
 infrared signals to monitor blood flow before and after the cold challenge.



 The PPG probe is fixed onto a fleshy part of the finger whilst a pressure cuff is
 wrapped around the base of the finger. The principle is similar to the measurement
 of ankle-brachial pressure index. The cuff is inflated until a wavefore is no longer

 detected, and gradually deflated. The pressure at which the signal reappears is the
 digital pressure.   Small pneumatic cuffs are used to determine finger perfusion using photoplethysmography
        sensors before and after immersion in cold water.  The test can be used to determine vasos-

 With this patient suffering from ischaemia on her right ring finger, the PPG   pastic diseases.
 waveform is notably diminished compared to the left.



 The process is repeated with her hands immersed in ice-cold water for 2 minutes.
 In this case, the right ring finger did not have a signal after 30 minutes, indicating
 profound vasoconstriction of the digital artery. As he finger rewarmed, the signal

 returned.
                                 A complete version of the COLD STIMULATION TEST