Page 35 - Virtual Vascular Vol 10
P. 35

While immediate angiographic results are good, placing a stent across the knee

 joint may have long term problems of stent fracture.  The stent is subject to con-  A 71-year old lady has a small 4.5cm AAA.  She had an X-ray of her knees for de-
 stant stress from knee joint flexion and patency is inferior to above-knee stent-  generation.  What do you see?
 ing.  Note also the extensive calcification of the collaterals and tibial arteries.



 34                                                                                                            35